Comparison of microarray analysis of fine needle aspirates and tissue specimen in thyroid nodule diagnosis.
Kundel A, Zarnegar R, Kato M, Moo TA, Zhu B, Scognamiglio T, Fahey TJ 3rd
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to compare gene clustering by microarray technology of thyroid nodule specimens collected by ex-vivo FNA and those from whole tissue.
Summary of Findings
Expression clustering based on 61 genes known to be differentially expressed between benign and malignant thyroid tumors properly clustered all 13 FNA specimens and 12 tissue specimens with their pathological diagnosis. Overall clustering analysis of FNA specimens was 100% sensitive, specific and accurate. Clustering analysis of whole tissue specimens was 85.7% specific, 100% sensitive and 92.3% accurate, as one tissue specimen improperly clustered as benign which the authors attribute to sampling error or heterogeneity within the tumor. When all gene expression was compared between the two collection methods, 67 genes were found to be differentially expressed. The 6 genes that were elevated in FNA specimens were hemoglobin subgroups and the S100 calcium binding protein A8. The 61 genes that were depressed in FNA specimens were predominantly matrix proteins, laminins and collagens. The authors attribute the differential expression between FNA and tissue specimens to reflect the enrichment of follicular cells in the specimens collected by FNA. The authors conclude that ex-vivo FNA can be used for analytical microarray diagnosis with a high degree of accuracy.
Biospecimens
TissueThyroid GlandPreservation Types
FrozenDiagnoses
NeoplasticBenignNeoplasticCarcinomaPlatforms
RNADNA microarrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition BenignMalignantBiospecimen Acquisition Method of tissue acquisition Fine needle aspirationSurgical resection