Skip to main content

Comparison of microarray analysis of fine needle aspirates and tissue specimen in thyroid nodule diagnosis.

Kundel A, Zarnegar R, Kato M, Moo TA, Zhu B, Scognamiglio T, Fahey TJ 3rd

Publication: Diagn Mol Pathol (2010) • Vol 19 • Page 9-14PMID: 20186006View on PubMed

Purpose

The purpose of this paper was to determine if collection of thyroid biospecimens by fine needle aspiration (FNA) versus whole tissue affects gene expression quantification by microarray.

Conclusion

Overall clustering analysis of a 61 gene subset was 100% sensitive, specific and accurate for FNA specimens, and 85.7% specific, 100% sensitive and 92.3% accurate for tissue specimens. In total, 67 genes were found to be differentially expressed among procurement methods, with 6 genes elevated and 61 genes depressed in FNA specimens compared to paired tissue specimens. The authors conclude that ex-vivo FNA can be used for analytical microarray diagnosis with a high degree of accuracy but that there are collection method specific differences in expression not related to diagnostic criteria.

Studies (1)

Purpose

The purpose of this study was to compare gene clustering by microarray technology of thyroid nodule specimens collected by ex-vivo FNA and those from whole tissue.

Summary of Findings

Expression clustering based on 61 genes known to be differentially expressed between benign and malignant thyroid tumors properly clustered all 13 FNA specimens and 12 tissue specimens with their pathological diagnosis. Overall clustering analysis of FNA specimens was 100% sensitive, specific and accurate. Clustering analysis of whole tissue specimens was 85.7% specific, 100% sensitive and 92.3% accurate, as one tissue specimen improperly clustered as benign which the authors attribute to sampling error or heterogeneity within the tumor. When all gene expression was compared between the two collection methods, 67 genes were found to be differentially expressed. The 6 genes that were elevated in FNA specimens were hemoglobin subgroups and the S100 calcium binding protein A8. The 61 genes that were depressed in FNA specimens were predominantly matrix proteins, laminins and collagens. The authors attribute the differential expression between FNA and tissue specimens to reflect the enrichment of follicular cells in the specimens collected by FNA. The authors conclude that ex-vivo FNA can be used for analytical microarray diagnosis with a high degree of accuracy.

  • Biospecimens

    TissueThyroid Gland
  • Preservation Types

    Frozen
  • Diagnoses

    NeoplasticBenign
    NeoplasticCarcinoma
  • Platforms

    RNADNA microarray
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Benign
    Malignant
    Biospecimen AcquisitionMethod of tissue acquisition
    Fine needle aspiration
    Surgical resection