Robust microRNA stability in degraded RNA preparations from human tissue and cell samples.
Jung M, Schaefer A, Steiner I, Kempkensteffen C, Stephan C, Erbersdobler A, Jung K
Purpose
Conclusion
Studies (3)
Purpose
The purpose of this study was to investigate the effect of reduced RNA quality (RIN value) on quantification of select mRNA transcripts from kidney and prostate by real-time RT-PCR (qRT-PCR).
Summary of Findings
mRNA CT values increased with declining RIN for all transcripts surveyed in renal (TBP, CDH16, and PPIA) and prostate tissues (HPRT1, HIF1A, and KLK3). CT value differences were most apparent in kidney specimens with CT values declining linearly by approximately 4 CTs between specimens with a RIN of 3 and those with a RIN of 8. In prostate specimens, the CT differences between the lowest (RIN = 3) and highest (RIN= 7.2) scores were <2 CTs. The effect of RIN values became even more apparent after normalization. Normalized mRNA values in both prostate and kidney specimens were significantly lower in all samples with a RIN less than 4.9 versus those with a RIN greater than 6.2 (p<0.005). The authors conclude that prolonged thaw results in decreased RIN score and the decline in RIN score corresponds with decreased quantifiability of mRNA transcripts by real-time qPCR.
Biospecimens
TissueKidneyTissueProstatePreservation Types
FrozenRNAlaterDiagnoses
NeoplasticNormal AdjacentPlatforms
RNAReal-time qRT-PCRRNAAutomated electrophoresis/BioanalyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location KidneyProstateAutomated electrophoresis/Bioanalyzer Specific Quality metrics RIN < 4RIN < 4.9RIN > 6RIN > 6.2Real-time qRT-PCR Specific Targeted nucleic acid Cadherin 16 (CDH16)Hypoxanthine phosphoribosyltransferase 1( HPRT1)Hypoxia inducible factor 1A (HIF1A)Kalikrein-related peptidase 3 (KLK3)Peptidylprolyl isomerase A (PPIA)TATA binding protein (TBP)
Purpose
The purpose of this study was to investigate the effect of reduced RNA quality (RIN value) on quantification of select miRNA transcripts from kidney and prostate by real-time RT-PCR (qRT-PCR).
Summary of Findings
miRNA was measurable by real-time qPCR in all RNA samples with a RIN greater than 3. No effect of declining RIN was observed on prostate miRNA (miR-96, miR-130b, miR-149, miR205, miR-222) cycle threshold (CT) values. In renal tissue, miR-141 and miR-200c CT values were stable independent of RIN value, but the slopes of the regression lines from miR-155 and mIR-210 differed significantly from 0. Further analysis revealed that quantified cycle differences for miR-155 and mIR-210 at the lowest RIN was within the expected experimental variability. Normalization of miRNA levels to cDNA calibration curves revealed no effect of RIN value on miRNA transcript level. The authors conclude that miRNA is stable and may still be accurately quantified in specimens with a RIN value as low as 3.0.
Biospecimens
TissueKidneyTissueProstatePreservation Types
FrozenRNAlaterDiagnoses
NeoplasticNormal AdjacentPlatforms
RNAReal-time qRT-PCRRNAAutomated electrophoresis/BioanalyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location KidneyProstateAutomated electrophoresis/Bioanalyzer Specific Quality metrics RIN < 4RIN < 4.9RIN > 6RIN > 6.2
Purpose
The purpose of this study was to investigate the effect of prolonged post-thaw duration (0-240 min) at 80 degrees C on the integrity of prostate and kidney RNA.
Summary of Findings
RNA integrity numbers (RIN) declined from original values of approximately 8.25 and 9.75 in kidney and prostate respectively during a thaw period at 80 degrees C. Degradation occurred rapidly with declining RIN score, and was first apparent after 5-10 min. Maximal degradation (RIN = 2.0) was observed between 60 and 90 min in prostate specimens, but maximal degradation had not yet been achieved in renal specimens after 240 min (RIN = 2.9). From these findings it is apparent the kinetics of RNA degradation are tissue specific, but proceed rapidly at 80 degrees C.
Biospecimens
TissueKidneyTissueProstatePreservation Types
FrozenRNAlaterDiagnoses
NeoplasticNormal AdjacentNeoplasticCarcinomaPlatforms
RNAAutomated electrophoresis/BioanalyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Thaw duration 0 min10 min120 min15 min180 min20 min240 min25 min30 min45 min5 min60 min90 min