Validation of putative reference genes for normalization of Q-RT-PCR data from paraffin-embedded lymphoid tissue.
Green TM, de Stricker K, Møller MB
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to evaluate RNA quality obtained from frozen versus formalin fixed paraffin embedded lymph nodes archived 5-11 years.
Summary of Findings
From 20 mg of paraffin embedded lymph nodes the authors were able to obtain between 14-446.7 ng/ul RNA with a 260/280 absorbance of 1.85-2.01. From 8 mg frozen lymph nodes 19-332.8 ng/ul RNA with a 260/280 absorbance of 2.03-2.11. The authors conclude that both methods allow for isolation of RNA of good purity and sufficient quantity.
Biospecimens
TissueLymph NodePreservation Types
FormalinFrozenDiagnoses
NeoplasticLymphomaPlatforms
RNASpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation Formalin (buffered)Snap frozen
Purpose
The purpose of this study was to determine if FFPE tissues differ in terms of real-time RT- PCR amplified reference genes compared to case-matched frozen tissue and the effect of amplicon size.
Summary of Findings
The ability to amplify transcripts by real-time RT-PCR varied between fixation methods and with amplicon length. Cycle threshold (Ct) values obtained from FFPE samples were 3-10 Ct values higher then those from frozen tissue indicating preservative dependent variance in the amplification of different transcripts. The authors speculate this is due to differences in degradation sensitivity between transcripts. It was found that in matched frozen and FFPE specimens transcript normalization with beta-glucoronidase (GUSB) and TATA box binding protein (TBP) together resulted in a pearson coefficient of 0.93 (P<0.01). Adding a third normalizer gene resulted in a decreased pearson coefficient. Pearson coefficients of 0.74 and 0.83 were obtained for comparisons between amplicons of different sizes of the same target transcript for frozen and FFPE samples, respectively. It was noted that the change in ranking of normalizer amplicons between preservative methods and the differential effect of size means any real-time PCR assay used in a study with multiple specimen preservation methods must be validated for each preservation method and may require the use of multiple normalizer genes. Preservation method also differentially affects amplification of amplicons of differing length so multiple target amplicons may also be necessary.
Biospecimens
TissueLymph NodePreservation Types
FormalinFrozenDiagnoses
NeoplasticLymphomaNormalPlatforms
RNAReal-time qRT-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation Formalin (buffered)Snap frozenReal-time qRT-PCR Specific Length of gene fragment 105 bp53 bp62 bp63 bp68 bp69 bp72 bp76 bp81 bp82 bp88 bp92 bpReal-time qRT-PCR Specific Targeted nucleic acid ABLB2MGAPDHGUSBPRKG1TBP