Long-term stability of coagulation variables: Protein S as a biomarker for preanalytical storage-related variations in human plasma.
Betsou F, Roussel B, Guillaume N, Lefrère JJ
Purpose
The aim of this paper was to identify a marker in plasma that can serve as a hallmark of frozen storage-induced alterations in protein levels.
Conclusion
Protein S and factor VIII activities were significantly and robustly reduced in plasma specimens after 9 years of storage at -80 degrees C compared to case-matched controls processed the day of collection, although protein S levels alone fell below normal physiological levels. Alterations in activity were not attributable to freeze-thaw cycling or the duration or temperature of post-thaw storage.
Studies (2)
Purpose
The aim of this study was to identify a marker in plasma that can serve as a hallmark of frozen storage-induced alterations in protein levels. Ten coagulation factors were examined on the day of collection and after 9 years of frozen storage at -80 degrees C after a single freeze-thaw cycle.
Summary of Findings
Plasma storage at -80 degrees C for 9 years resulted in significant reductions (by 68%) in factor VIII activity although values remained within the clinically normal range. Protein S activity decreased by 71% compared to day 0, and was 9% below the lower threshold for a clinically normal diagnosis, implying it holds potential as candidate biomarker for quality control. Prolonged frozen storage also resulted in significant changes in PT, antithrombin, fibrinogen, factor II (reduced), and APTT, protein C (increased).
Biospecimens
FluidPlasmaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
ProteinHematology/ auto analyzerGlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 d9 yHematology/ auto analyzer Specific Targeted peptide/protein AntithrombinD-dimersFactor IIFactor VIIFactor VIIIFibrinogenPartial thromboplastin timeProtein CProtein SProthrombin time
Purpose
The aim of this study was to determine if the number of freeze-thaw cycles or the temperature and duration of post-thaw storage influences protein S or factor VIII levels or activities.
Summary of Findings
While protein S and factor VIII levels and activity were not significantly altered by freeze-thaw cycling or post-thaw storage, levels were slightly elevated and reduced, respectively, after 10 freeze-thaw cycles or post-thaw storage at room temperature (for 24 or 48 h) compared to case-matched controls processed and analyzed the day of collection.
Biospecimens
FluidPlasmaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
GlycoproteinHematology/ auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Freeze/thaw cycling 0 cycles1 cycle10 cyclesStorage Post-thaw duration 12 h at 37 degrees C24 h at 20 degrees C24 h at 37 degrees C48 h at 20 degrees CHematology/ auto analyzer Specific Targeted peptide/protein Factor VIIIProtein S