Loss of tumor marker-immunostaining intensity on stored paraffin slides of breast cancer.
Jacobs TW, Prioleau JE, Stillman IE, Schnitt SJ
Purpose
The purpose of this paper was to determine if storage temperature and duration affect immunostaining in formalin-fixed paraffin-embedded (FFPE) tissue sections, and whether coating slides in paraffin prior to storage improves preservation.
Conclusion
Storage of slide-mounted tissue sections for 12 weeks adversely affected p53, estrogen receptor (ER), Bcl-2, and Factor VIII immunostaining. p53 immunostaining was altered in a time-dependent manner, with significant reductions in intensity observed after as little as 2 weeks. Storage of slides at 4 degrees C partially attenuated the magnitude of effects for p53 immunostaining compared to room temperature storage. Coating slides in paraffin prior to storage did not alter storage-dependent alterations in p53 immunostaining irrespective of storage temperature.
Studies (2)
Purpose
The purpose of this study was to determine if p53, estrogen receptor (ER), Bcl-2, and Factor VIII immunostaining are impacted by room temperature storage of FFPE slide-mounted tissue sections for 12 weeks.
Summary of Findings
In the majority of specimens examined, immunostaining was reduced for all four antigens after 12 weeks of slide storage at room temperature compared to freshly sectioned controls.
Biospecimens
TissueBreastPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaPlatforms
ProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 d12 weeksStorage Storage temperature Room temperatureImmunohistochemistry Specific Targeted peptide/protein Bcl-2ERFactor VIIIp53
Purpose
The purpose of this study was to conduct a time course analysis of p53 immunostaining after slide storage at room temperature or 4 degrees C for up to 12 weeks, and to determine the influence coating the slide in paraffin prior to storage.
Summary of Findings
The intensity of p53 immunostaining was significantly affected by the duration of slide storage. Staining intensity decreased to 30%, 17%, 10%, and 8% that of freshly sectioned controls after room temperature storage for 2, 4, 8, and 12 weeks in comparison to fresh cut controls. Slides stored at 4 degrees C also exhibited a time-dependent decrease in immunostaining intensity, although effects were less robust: 56%, 42%, 28%, 33% that of freshly sectioned controls after 2, 4, 8, and 12 weeks of storage. Coating slides in paraffin prior to storage did not attenuate the observed reductions in intensity irrespective of storage temperature.
Biospecimens
TissueBreastPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaPlatforms
ProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Type of slide Paraffin-coated slideUntreated slideStorage Storage duration 0 d12 weeks2 weeks4 weeks8 weeksStorage Storage temperature 4 degrees CRoom temperatureImmunohistochemistry Specific Targeted peptide/protein p53