Skip to main content

Cryopreservation and long-term liquid nitrogen storage of peripheral blood mononuclear cells for flow cytometry analysis: effects on cell subset proportions and fluorescence intensity.

Tollerud DJ, Brown LM, Clark JW, Neuland CY, Mann DL, Pankiw-Trost LK, Blattner WA

Publication: J Clin Lab Anal (1991) • Vol 5 • Page 255-61PMID: 1890539View on PubMed

Purpose

The purpose of this paper was to determine if (1) proportions of viable peripheral blood mononuclear cell (PBMC) subsets, or (2) the intensity of fluorescence immunostaining were altered by cryopreservation and short- and long-term storage in liquid nitrogen.

Conclusion

The proportions of PBMC subsets exhibiting positive immunostaining, as well as the intensity of fluorescence, were influenced by cryopreservation and the storage duration in liquid nitrogen in an antigen-specific manner. While the magnitude of effects were modest, differences were statistically significant.

Studies (1)

Purpose

The purpose of this study was to determine if (1) proportions of viable peripheral blood mononuclear cell (PBMC) subsets, or (2) the intensity of fluorescence immunostaining were altered by cryopreservation and short- and long-term storage in liquid nitrogen.

Summary of Findings

Cryopreservation of isolated PBMC and storage in liquid nitrogen for 1-2 h resulted in a modest but significant increase in the percentage of HLA-DR+ and HLe-1 cells compared to freshly procured specimens, while the proportion of cells displaying immunoreactivity for the following antigens were unaffected: CD3+, CD4+, CD8+, CD16+, CD19+, CD14+. Storage in liquid nitrogen for 12 months resulted in approximate 3 and 6% decreases in the number of CD8+ and CD19+ cells, respectively, compared to samples cryopreserved for 1-2 h, while proportions of CD3+, CD4+, CD16+, and HLA-DR+ cells were unaffected. Proportions of CD14+ cells exhibited a high degree of variability independent of storage duration in PBMC samples, although a modest increase was observed in leukopheresis samples after 2 months of frozen storage compared to values observed after 9 months. Mean fluorescence intensity was affected in an antigen-dependent manner with respect to the duration of frozen storage, with significant decreases in CD4+ and CD8+ overtime.

  • Biospecimens

    CellWhite Cells
  • Preservation Types

    FrozenNone (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeFlow cytometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Frozen
    None (fresh)
    StorageStorage duration
    0 h
    1 month
    1-2 h
    12 months
    2 months
    20 months
    3 months
    6 months
    9 months