Cryopreservation and long-term liquid nitrogen storage of peripheral blood mononuclear cells for flow cytometry analysis: effects on cell subset proportions and fluorescence intensity.
Tollerud DJ, Brown LM, Clark JW, Neuland CY, Mann DL, Pankiw-Trost LK, Blattner WA
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to determine if (1) proportions of viable peripheral blood mononuclear cell (PBMC) subsets, or (2) the intensity of fluorescence immunostaining were altered by cryopreservation and short- and long-term storage in liquid nitrogen.
Summary of Findings
Cryopreservation of isolated PBMC and storage in liquid nitrogen for 1-2 h resulted in a modest but significant increase in the percentage of HLA-DR+ and HLe-1 cells compared to freshly procured specimens, while the proportion of cells displaying immunoreactivity for the following antigens were unaffected: CD3+, CD4+, CD8+, CD16+, CD19+, CD14+. Storage in liquid nitrogen for 12 months resulted in approximate 3 and 6% decreases in the number of CD8+ and CD19+ cells, respectively, compared to samples cryopreserved for 1-2 h, while proportions of CD3+, CD4+, CD16+, and HLA-DR+ cells were unaffected. Proportions of CD14+ cells exhibited a high degree of variability independent of storage duration in PBMC samples, although a modest increase was observed in leukopheresis samples after 2 months of frozen storage compared to values observed after 9 months. Mean fluorescence intensity was affected in an antigen-dependent manner with respect to the duration of frozen storage, with significant decreases in CD4+ and CD8+ overtime.
Biospecimens
CellWhite CellsPreservation Types
FrozenNone (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeFlow cytometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation FrozenNone (fresh)Storage Storage duration 0 h1 month1-2 h12 months2 months20 months3 months6 months9 months