Skip to main content

A comparative study of the quality of DNA obtained from fresh frozen and formalin-fixed decalcified paraffin-embedded bone marrow trephine biopsy specimens using two different methods.

Talaulikar D, Gray JX, Shadbolt B, McNiven M, Dahlstrom JE

Publication: J Clin Pathol (2008) • Vol 61 • Page 119-23PMID: 17545562View on PubMed

Purpose

This paper compared the yield and amplification success of DNA extracted from fresh frozen and decalcified, formalin-fixed, paraffin-embedded (FFPE) specimens using two methods of amplification.

Conclusion

While DNA yields were comparable among differentially preserved specimens, DNA amplification results were dependent upon the method of biospecimen preservation. Successful amplification of DNA extracted from FFPE bone marrow biopsy specimens via semi-quantitative PCR was inversely proportional to the size of the amplified fragment, a trend that was not observed with among fresh frozen specimens. Real-time quantitative PCR (qPCR) of FFPE specimens required approximately 10 additional cycles to cross threshold compared to fresh frozen specimens. Collectively, data suggest that FFPE induces DNA fragmentation and reduces the abundance of amplifiable DNA.

Studies (1)

Purpose

The purpose of this study was to compare the yield and amplification success of DNA extracted from fresh frozen and decalcified, formalin-fixed, paraffin-embedded (FFPE) specimens using two methods of amplification.

Summary of Findings

Fresh frozen and decalcified FFPE bone marrow specimens did not differ significantly in the concentration of extracted DNA. PCR success rates did differ among differentially preserved specimens with regard to the length of the PCR generated amplicon, with 100, 60, and 10% success rates for 96, 300, and 600 bp fragments in FFPE specimens, respectively, compared to a 100% success rate for all amplicon sizes among fresh frozen specimens. DNA extracted from FFPE specimens subjected to real-time qPCR amplification required approximately 10 additional cycles compared to DNA extracted from fresh frozen specimens.

  • Biospecimens

    TissueBone Marrow
  • Preservation Types

    FormalinFrozen
  • Diagnoses

    NeoplasticLeukemia
    Other diagnoses
  • Platforms

    DNASpectrophotometry
    DNAPCR
    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Frozen
    PCR SpecificLength of gene fragment
    200 bp
    300 bp
    400 bp
    600 bp
    96 bp
    PCR SpecificTechnology platform
    In Vivo Scribe IgH clonality kit
    Real-time qPCR