Skip to main content

Preanalytical factors affecting RIA measurement of plasma kisspeptin.

Ramachandran R, Patterson M, Murphy KG, Dhillo WS, Patel S, Kazarian A, Ghatei MA, Bloom SR

Publication: Clin Chem (2008) • Vol 54 • Page 615-7PMID: 18310154View on PubMed

Purpose

The purpose of this paper was to determine if radioimmunoassay-quantified plasma and serum kisspeptin levels are affected by a preprocessing room temperature delay, the type of anticoagulant used, or multiple freeze-thaw cycles.

Conclusion

Kisspeptin immunoreactivity (IR) was unstable in serum specimens after a room temperature preprocessing delay of 1 h or more. Kisspeptin IR in plasma EDTA-treated specimens was stable at room temperature for up to 4 h prior to centrifugation. Freeze-thaw cycling (up to 4 cycles) did not affect IR in plasma specimens treated with EDTA or lithium heparin.

Studies (3)

Purpose

This study examined the stability of kisspeptin immunoreactivity (IR) in serum specimens subjected to a preprocessing room temperature delay of 0-4 h. Kisspeptin IR levels in serum and immediately processed plasma specimens were also compared. Biospecimens were collected from healthy pregnant women for all studies.

Summary of Findings

In serum specimens, detectable kisspeptin IR was limited to samples processed immediately (0 h). Kisspeptin IR levels were significantly lower in immediately processed serum specimens compared to corresponding plasma specimens.

  • Biospecimens

    FluidSerum
    FluidPlasma
    FluidBlood
  • Preservation Types

    Frozen
  • Diagnoses

    Pregnant
  • Platforms

    PeptideRadioimmunoassay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    StorageTime at room temperature
    0 h
    1 h
    2 h
    4 h