Effect of storage conditions on the extraction of PCR-quality genomic DNA from saliva.
Ng DP, Koh D, Choo SG, Ng V, Fu Q
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to compare the quantity and quality of genomic DNA extracted from saliva specimens that were processed and analyzed immediately or differentially stored as whole specimens or cell pellets.
Summary of Findings
While the quality of extracted genomic DNA was comparable across storage regimes, quantity varied widely both among storage conditions and specimens. Although PCR analysis yielded discrete and appropriate bands for all specimens, amplicon intensity was dependent on storage conditions and timing, despite normalization of template amount. Saliva specimens processed and analyzed the same day as collection produced the most abundant amplicons, although whole specimens stored at 4 degrees C for 7 days, and those stored as pellets at -70 degrees C for 7 days produced PCR amplicons of statistically similar intensity.
Biospecimens
FluidSalivaCellBuccalPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
DNASpectrophotometryDNAPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 d1 month (at -70 degrees C)7 d (at 4 or -70 degrees C)Storage Storage temperature -70 degrees C4 degrees C