The stability of serum hepatitis C viral RNA in various handling and storage conditions.

Fong TL, Charboneau F, Valinluck B, Govindarajan S

Publication: Arch Pathol Lab Med (1993) • Vol 117 • Page 150-1PMID: 8381268View on PubMed

Purpose

The purpose of this paper was to determine if serum storage at room temperature or 4 degrees C, or freeze-thaw cycling impacts RT-PCR detection of hepatitis C viral RNA.

Conclusion

Hepatitis C viral RNA was stable in serum specimens stored for 5 days at room temperature or 4 degrees C, as well as those subjected to 5 freeze-thaw cycles.

Studies (1)

Purpose

The purpose of this study was to determine if serum storage at room temperature or 4 degrees C, or freeze-thaw cycling impacts RT-PCR detection of hepatitis C viral RNA. Specimens were centrifuged and separated prior to storage.

Summary of Findings

Detection of hepatitis C viral RNA by nested RT-PCR was not influenced by 5 days of serum storage at room temperature or 4 degrees C or 5 freeze-thaw cycles.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Hepatitis
  • Platforms

    RNART-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageFreeze/thaw cycling
    1 cycle
    5 cycles
    StorageStorage duration
    0 d
    5 d
    StorageStorage temperature
    4 degrees C
    Room temperature