Skip to main content

Soluble CD40 ligand as a biomarker for storage-related preanalytic variations of human serum.

Lengellé J, Panopoulos E, Betsou F

Publication: Cytokine (2008) • Vol 44 • Page 275-82PMID: 18851919View on PubMed

Purpose

The purpose of this paper was to validate CD40 ligand as a biomarker for improper serum specimen handling (extended post-separation delays at varying temperatures, and extensive freeze-thaw cycling).

Conclusion

The authors conclude that CD40 ligand immunoreactivity is sensitive to serum specimen handling, and is thus a good biomarker candidate for specimen screening. CD40 ligand immunoreactivity decreased significantly in serum specimens stored for 24 hours at 16, 20, or 37 degrees C post-separation, but was unaffected by up to 10 freeze-thaw cycles.

Studies (1)

Purpose

The purpose of this study was to validate CD40 ligand as a biomarker for improper serum specimen handling (extended post-separation delays at varying temperatures, and extensive freeze-thaw cycling).

Summary of Findings

CD40 ligand immunoreactivity was abolished in serum specimens stored at 37 degrees C for 24 hours after separation, or significantly reduced in specimens stored at 16 or 20 degrees C for 24 hours. Multiple linear regression analysis suggested critical exposure thresholds of 12 hours at 37 degrees C and 48 hours at 20 degrees C for serum CD40 ligand stability. Western blot analysis buttressed ELISA findings but provided no evidence of protein degradation. CD40 ligand was stable for up to 10 freeze-thaw cycles.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Not specified
  • Platforms

    ProteinELISA
    ProteinImmunoassay
    ProteinWestern blot
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageFreeze/thaw cycling
    1 cycle
    10 cycles
    5 cycles
    StorageStorage duration
    12 h
    24 h
    4 h
    48 h
    StorageStorage temperature
    16 degrees C
    20 degrees C
    37 degrees C