Skip to main content

Limits of preservation of samples for urine strip tests and particle counting.

Kouri T, Malminiemi O, Penders J, Pelkonen V, Vuotari L, Delanghe J

Publication: Clin Chem Lab Med (2008) • Vol 46 • Page 703-13PMID: 18839472View on PubMed

Purpose

The purpose of this paper was to identify adequate (a) preservation methods, and (b) storage threshold durations and temperatures for urinary analytes.

Conclusion

For test strip analysis, preservative-free collection tubes were adequate for urine specimens processed within 8 hours of collection. Particle counting or bacterial analytes assessment should be completed within 8 hours of urine collection when using new BDC&S Plus and UAP tubes or Greiner Bio-One Stabilizer preservative tubes. Boric acid was the only preservative that generated false test strip results. For delays up to 72 hours, refrigeration of specimens at 4 degrees C proved to be the best method of preservation.

Studies (1)

Purpose

The purpose of this study was to identify adequate (a) preservation methods, and (b) storage threshold durations and temperatures for urinary analytes.

Summary of Findings

For test strip analysis, preservative-free collection tubes were adequate for urine specimens processed within 8 hours of collection. Particle counting or bacterial analytes assessment should be completed within 8 hours of urine collection when using new BD C&S Plus and UAP tubes or Greiner Bio-One Stabilizer preservative tubes. Boric acid was the only preservative that generated false test strip results. For delays up to 72 hours, refrigeration of specimens at 4 degrees C proved to be the best method of preservation.
  • Biospecimens

    FluidUrine
  • Preservation Types

    Other Preservative
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    ProteinClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    MorphologyLight microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    BD Glass C&S tube with boric acid-formiate
    BD Plus Conical tube
    BD Plus Culture and Sensitivity (C&S) tube
    BD Plus UAP Conical PET tube with chlorhexidine-based preservative
    BD Plus Urinalysis Preservative tube
    Greiner's Vacuette Stabilur tube
    Non-preservative polypropylene tube
    Sarstedt Urin-Monovette tube
    StorageStorage duration
    1 d
    2 d
    3 d
    5-6 h
    StorageStorage temperature
    20 degrees C
    4 degrees C