Skip to main content

The quality of DNA extracted from liquid or dried blood is not adversely affected by storage at 4 degrees C for up to 24 h.

Halsall A, Ravetto P, Reyes Y, Thelwell N, Davidson A, Gaut R, Little S

Publication: Int J Epidemiol (2008) • Vol 37 Suppl 1 • Page i7-10PMID: 18263648View on PubMed

Purpose

The purpose of this paper was to determine if storage of whole blood for 24 hours at 4 degrees C or as dried blood spots at ambient temperature on different types of storage cards impacts DNA yield or quality.

Conclusion

DNA extracted from dried blood spotted onto collection cards generated lower yields of poor quality compared to immediately processed whole blood controls. While Biospot paper resulted in the greatest DNA yield and promise for subsequent molecular analyses among the storage cards tested, DNA fragmentation was evident. DNA quality was not affected by storage of whole blood liquid specimens at 4 degrees C for 24 hours.

Studies (2)

Purpose

The aim of this study was to determine if storage of whole blood at 4 degrees C for 24 hours impacts the quality or quantity of DNA extracted from harvested white blood cells.

Summary of Findings

DNA yields did not differ between specimens processed immediately and those stored for 24 hours at 4 degrees C prior to processing. DNA quality, as determined by qPCR and SNP analysis was unaffected by whole blood storage at 4 degrees C for 24 hours.

  • Biospecimens

    FluidBlood
    CellWhite Cells
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    DNAReal-time qPCR
    DNASNP assay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    0 h
    24 h