Skip to main content

A GC-TOF-MS study of the stability of serum and urine metabolomes during the UK Biobank sample collection and preparation protocols.

Dunn WB, Broadhurst D, Ellis DI, Brown M, Halsall A, O'Hagan S, Spasic I, Tseng A, Kell DB

Publication: Int J Epidemiol (2008) • Vol 37 Suppl 1 • Page i23-30PMID: 18381390View on PubMed

Purpose

The purpose of this paper was to determine if metabolic profiles of serum and urine are altered by a 24 hour processing delay (at 4 degrees C) prior to freezing.

Conclusion

For both serum and urine specimens, samples processed immediately and those retained for 24 hours at 4 degrees C before processing and freezing generated similar metabolic profiles.

Studies (2)

Purpose

The objective of the study was to observe whether the metabolomic composition of serum changes when stored at 4 degrees C for 24 h before being frozen at -80 degrees C, in comparison with being frozen immediately at -80 degrees C after sample preparation.

Summary of Findings

Serum samples processed immediately and those retained for 24 hour at 4 degrees C before processing and freezing generated similar metabolic profiles, and exhibited less variability than observed between individuals.
  • Biospecimens

    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    Small moleculeGC-TOF-MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    24 h
    30 min
    StorageStorage temperature
    -80 degrees C
    4 degrees C