Preanalytical variability in laboratory testing: influence of the blood drawing technique.

Lippi G, Salvagno GL, Brocco G, Guidi GC

Publication: Clin Chem Lab Med (2005) • Vol 43 • Page 319-25PMID: 15843239View on PubMed

Purpose

The purpose of this paper was to determine if routine hematological and clinical chemistry parameters differ as a result of the type of needle used during blood draw (traditional straight needle versus butterfly device).

Conclusion

Of the 43 parameters measured, only serum sodium levels, white blood cell counts, and platelet counts significantly varied between the two blood draw techniques.

Studies (1)

Purpose

The purpose of this study was to determine if routine hematological and clinical chemistry parameters differ as a result of the type of needle used during blood draw (traditional straight needle versus butterfly device).

Summary of Findings

Of the 43 parameters investigated, only platelet count and white blood cell count differed significantly due to the type of blood collection device used, which were lower in specimens collected with the butterfly device compared to those collected with a straight needle. However, as determined by coefficient of variation, serum sodium also differed among differentially collected specimens.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    CarbohydrateClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    LipidClinical chemistry/auto analyzer
    ProteinSpectrophotometry
    ProteinClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionNeedle gauge
    21-Gauge butterfly device
    21-Gauge straight needle