Effect of blood collection tube types on the measurement of human epidermal growth factor.

Yucel A, Karakus R, Cemalettin A

Publication: J Immunoassay Immunochem (2007) • Vol 28 • Page 47-60PMID: 17236396View on PubMed

Purpose

The purpose of this paper was to evaluate whether the type of blood-storage tube influenced the measurable levels of epidermal growth factor (EGF). Findings of higher EGF levels in serum than plasma and in female than male subjects were further investigated.

Conclusion

The levels of EGF measured in serum from the same patients and the same blood draw were significantly different among the six storage tube types measured. Levels were undetectable in plasma; serum EGF levels were likely detectable due to release of EGF from platelets during refrigerated storage. EGF levels were significantly higher in female compared to male subjects.

Studies (2)

Purpose

The purpose of this study was to evaluate whether blood EGF levels were influenced by the type of blood-storage tube. Blood taken in one draw was separated into six different tubes.

Summary of Findings

EGF peptide levels were dependent upon the type of collection tube used; EGF levels were highest in polystyrene tubes, followed by glass, plastic with clot activator, plastic without clot activator, polypropylene, and plastic tubes with EDTA. EGF levels in blood separated sera differed based upon glass versus polypropylene collection tube, and polystyrene versus vac-gel, vac no-gel, and polypropylene tubes, but not glass versus polystyrene tubes. Plasma separated specimens collected in plastic tubes failed to generate detectable EGF levels. The authors hypothesize that the difference among EGF plasma and serum levels may be due to innate and continuing platelet activity during refrigerated storage.

  • Biospecimens

    FluidPlasma
    FluidSerum
    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    PeptideELISA
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    BD Vacutainer SST II Plus serum separation tube
    Plastic Vacuette K2E plasma separtion tube w/ EDTA
    Plastic Vacuette Z-serum clot activator tube
    Polypropylene with conical bottom
    Polystyrene tissue culture tube
    Round bottom glass tube
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum