Skip to main content

Potential interferences from blood collection tubes in mass spectrometric analyses of serum polypeptides.

Drake SK, Bowen RA, Remaley AT, Hortin GL

Publication: Clin Chem (2004) • Vol 50 • Page 2398-401PMID: 15563493View on PubMed

Purpose

The purpose of this paper was to determine whether different types of blood collection tubes shed exogenous molecules capable of interfering with MALDI-TOF mass spectrometry peptide analysis.

Conclusion

The majority of serum collection tubes tested shed polymers that can be detected in the 1000-3000 m/z range, potentially compromising the analysis of low-molecular weight peptides through mass spectrometry; while the majority of plasma collection tubes tested did not generated exogenous mass spectrometry peaks. The authors suggest collection tube type should be standardized and screened for interference before analysis.

Studies (1)

Purpose

The purpose of this study was to determine whether different types of blood collection tubes shed exogenous molecules capable of interfering with MALDI-TOF mass spectrometry peptide analysis. Both serum and plasma collection tubes were assessed by incubating saline in respective tubes at room temperature for 4 hours; biospecimens were not directly investigated.

Summary of Findings

With the exception of no-additive glass tubes all serum collection tubes generated a series of MALDI-TOF mass spectrometry peaks within the m/z range of 1000 to 3000; tubes from two different manufacturers produced similar results. Conversely, the majority of plasma collection tubes investigated did not yield peptide peaks suggesting minimal interference, including EDTA-containing plasma tubes, no-additive glass tubes with a glycerol coated stopper, and tubes containing citrate or heparin additives. Research-use plasma separator tubes containing protein stabilizing additives generated several peaks within the m/z range of 1050-6880.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    PeptideMALDI-TOF MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    10 ml Vacutainer Clot Activator Plus Plastic
    10 x 65 mm Glass Vacutainer
    2.5 ml Vacuette Z serum separator (clot activator)
    3 ml Vacutainer Plus 5.4 mg K2EDTA
    3.5 ml Vacutainer SST Gel and Clot Activator
    4 ml Vacuette Z serum separator (clot activator)
    4.5 ml Vacutainer buffered sodium citrate
    6 ml Vacutainer Plus sodium heparin
    7 ml Vacutainer SST Gel and Clot Activator
    8 ml Vacuette Z serum separator (clot activator)
    8.5 ml Plus Plastic EDTA separator