Skip to main content

Comparison of blood counts in venous, fingertip and arterial blood and their measurement variation.

Yang ZW, Yang SH, Chen L, Qu J, Zhu J, Tang Z

Publication: Clin Lab Haematol (2001) • Vol 23 • Page 155-9PMID: 11553055View on PubMed

Purpose

The purpose of this paper was to determine if cell counts, hemoglobin concentration, and hemocrit values are influenced by the location of blood draw (venous, arterial, capillary) or sequential collection.

Conclusion

Venous blood showed significantly higher erythrocyte counts and hemocrit than arterial blood. Capillary biospecimens contained higher total and large leucocyte counts. Measurements in venous blood showed lower coefficients of variation than capillary or arterial blood measurements. Significant differences among sequentially collected aliquots were limited to total leucocyte counts of fingertip collected specimens.

Studies (2)

Purpose

The purpose of this study was to determine if cell counts, hemoglobin concentration, and hemocrit values are influenced by the location of blood draw (venous, arterial, capillary).

Summary of Findings

Total leucocyte count and large leucocyte ratio were significantly higher in capillary compared to venous blood specimens. Erythrocyte count and hemocrit values were significantly lower in arterial compared to venous blood specimens. Statistical significance was unaffected whether pooled means or individual samples were compared. Capillary and arterial blood specimens exhibited greater variance for analyzed parameters than venous blood specimens.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeHematology/ auto analyzer
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionAnatomical location of blood draw
    Artery
    Capillary
    Vein