Skip to main content

Effects of fixative and fixation protocols on assessment of Her-2/neu oncogene amplification status by fluorescence in situ hybridization.

Willmore-Payne C, Metzger K, Layfield LJ

Publication: Appl Immunohistochem Mol Morphol (2007) • Vol 15 • Page 84-7PMID: 17536313View on PubMed

Purpose

The purpose of this paper was to compare fluorescence in situ hybridization (FISH) results for Her-2/neu gene amplification in case-matched breast cancer tumor specimens differentially preserved in formalin and six non-formalin-based fixatives.

Conclusion

O-Fix alone yielded FISH results comparable to formalin fixation. The other non-formalin-based fixatives examined resulted in high background or adversely impacted signal quantification, although these issues were prevented by fixing specimens in the primary fixative for 4 hours and subsequent processing in 10% neutral buffered formalin. UniFix failed to generate a FISH signal.

Studies (2)

Purpose

The purpose of this study was to compare FISH results for Her-2/neu gene amplification using the Vysis-FISH kit in case-matched tumor specimens differentially fixed in either formalin or one of five non-formalin-based fixatives.

Summary of Findings

Of the five formalin alternative fixatives evaluated, O-Fix alone yielded FISH results comparable to formalin fixation, while the other non-formalin-based fixatives generated high background (Prefer, GTF, Histochoice) or adversely affected counting accuracy (Pen-Fix).

  • Biospecimens

    TissueBreast
  • Preservation Types

    FormalinOther Preservative
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    DNAFISH
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    GTF
    Histochoice
    O-Fix
    Pen-fix
    Prefer