Evaluation of extraction methods from paraffin wax embedded tissues for PCR amplification of human and viral DNA.
Chan PK, Chan DP, To KF, Yu MY, Cheung JL, Cheng AF
Purpose
The purpose of this paper was to compare the PCR efficiency of three DNA extraction methods for formalin-fixed, paraffin-embedded (FFPE) specimens for two genes of interest.
Conclusion
The authors report that the Qiagen spin column extraction method yielded the highest PCR success rate for HPV analysis. Further, the predictive power of the beta-globin housekeeping gene for appropriate HPV amplification was highest with the Qiagen spin column method. Of note, PCR success rates were not only dependent on DNA extraction method, but the gene of interest and amplicon size as well.
Studies (1)
Purpose
The purpose of this study was to compare the PCR success rate of three DNA extraction methods for different amplicon lengths of beta-globin and the human papillomavirus.
Summary of Findings
Successful PCR analysis of FFPE specimens was dependent on the gene analyzed, amplicon length, and the method of DNA extraction. In general, shorter amplicons (15-355 bp) resulted in higher PCR success rates than longer amplicons (450-509 bp). For beta-globin analysis, microwave heating in a digestion buffer generated the highest PCR success rate, while Qiagen spin columns were the preferred DNA extraction method for HPV analysis. The authors note that DNA extraction by the Qiagen spin column method yielded the highest predictive value of the beta-globin housekeeping gene, with 90% of beta-globin positive samples generating an appropriate HPV product.
Biospecimens
TissueCervixPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaPlatforms
DNAPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Analyte Extraction and Purification Analyte isolation method Microwave heatingPhenol/ chloroformQiagen spin columnPCR Specific Length of gene fragment 150 bp355 bp450 bpPCR Specific Targeted nucleic acid Beta-globinHuman papillomavirus