Skip to main content

Rapid techniques for DNA extraction from routinely processed archival tissue for use in PCR.

Sepp R, Szabó I, Uda H, Sakamoto H

Publication: J Clin Pathol (1994) • Vol 47 • Page 318-23PMID: 8027368View on PubMed

Purpose

This paper evaluated the efficiency of polymerase chain reaction (PCR) amplification of DNA extracted from formalin-fixed, paraffin-embedded (FFPE) specimens using four different rapid DNA extraction methods, as well as investigated the influence of specimen size and prolonged DNA sample storage.

Conclusion

PCR efficiency was affected by specimen size, DNA extraction method, and prolonged DNA sample storage among FFPE specimens. DNA extracted from larger surgical (16 x 18 mm) performed better than smaller (1.7 x 2 mm) biopsy specimens for two of the three genes examined. PCR success and amplicon intensity were equivalent among specimens extracted by Chelex boiling, proteinase K digestion, and proteinase K digestion followed by Chelex boiling. PCR efficiency was adversely impacted by DNA sample storage for 3 months at -20 degrees C, although DNA isolated via proteinase K digestion yielded results superior to the other extraction methods examined.

Studies (2)

Purpose

The purpose of this study was to compare the utility of four rapid DNA extraction techniques among FFPE specimens (fixed for 24-48 h) for use in the PCR application. The tissue types evaluated included skin, soft tissue, tonsils, esophagus, duodenum, colon, pancreas, lung, kidney, urinary bladder, meninges, ovary, cervix, normal placenta, and endometrium, as well as non-Hodgkin's lymphoma. The amplified targets were portions of the p53, HPV, and IgH genes.

Summary of Findings

PCR amplification of larger surgical specimens was successful in all cases, producing a single product of predicted size and equal intensity for all DNA extraction methods examined. For smaller biopsy-sized specimens, DNA from 17-33% or 50-80% of specimens extracted using the boiling water method failed to produce a product or produced a product of reduced intensity, respectively. Single products of equivalent intensity were observed among biopsy-sized specimens extracted by Chelex-boiling, proteinase k digestion, or a combination of the two methods. The largest product size achieved (983 bp) was in large surgical specimens that underwent DNA extraction by proteinase K digestion or proteinase K digestion followed by Chelex boiling.

  • Biospecimens

    TissueCervix
    TissueSkin
    TissueTonsil
    TissueEsophagus
    TissueSmall Bowel
    TissueColorectal
    TissuePancreas
    TissueLung
    TissueKidney
    TissueBladder
    TissueBrain
    TissueOvary
    TissuePlacenta
    TissueEndometrium
    TissueLymph Node
    TissueOther
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
    Not specified
  • Platforms

    DNAPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of tissue acquisition
    Biopsy
    Surgical resection
    Biospecimen Aliquots and ComponentsAliquot size/volume
    1.7 mm X 2.0 mm (Biopsy specimen)
    16 mm X 18 mm (Surgical specimen)
    Analyte Extraction and PurificationAnalyte isolation method
    Boiling in 5% Chelex-100
    Boiling in distilled water
    Proteinase K
    Proteinase K and boiling in 5% Chelex-100
    PCR SpecificLength of gene fragment
    408 bp
    647 bp
    80-120 bp
    983 bp
    PCR SpecificTargeted nucleic acid
    HPV16
    IgH
    p53