Skip to main content

Development of an effective sample preparation method for the proteome analysis of body fluids using 2-D gel electrophoresis.

Joo WA, Lee DY, Kim CW

Publication: Biosci Biotechnol Biochem (2003) • Vol 67 • Page 1574PMID: 12913303View on PubMed

Purpose

The purpose of this paper was to validate a single protein extraction method for several human body fluids using a combined centrifugal filter device and a sample treating buffer for analysis with two-dimensional (2-D) gel electrophoresis.

Conclusion

The authors report that extraction using a centrifugal filter device and the zwitterionic detergent 3-3 (cholamidoprophy) dimethylammonio-1-propanesulfate (CHAPS) resulted in a nearly 90% protein recovery and high quality 2-D gel separation. The authors concluded that sample preparation using the centrifugal-filter/CHAPS is a more effective method for proteome analysis of body fluids with 2-D gel electrophoresis than classical protein extraction methods.

Studies (1)

Purpose

The purpose of this study was to optimize protein extraction from human body fluids using a combined centrifugal filter device and a sample treating buffer for analysis with 2-D gel electrophoresis. They compared this method with traditional methods of protein extraction for plasma, amniotic fluid, urine, and tears.

Summary of Findings

The authors report that extraction using a centrifugal filter device and the zwitterionic detergent CHAPS resulted in a nearly 90% protein recovery and high quality 2-D gel separation. Biospecimen location specific results are as follows: Plasma: Low-molecular-weight gel spots were more apparent with proteins extracted using the centrifugal-filter/CHAPS method than the hot sodium dodecyl sulfate (SDS) extraction. Amniotic fluid: Hot SDS and centrifugal-filter/CHAPS extractions yielded comparable results. Urine: Low-molecular-weight gel spots were significantly increased for proteins extracted using the centrifugal-filter/CHAPS methods compared to those extracted with dialysis alone. Tears: Many protein spots were apparent for proteins extracted with the centrifugal-filter/CHAPS method, which enabled good isoelectric focusing.
  • Biospecimens

    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Protein1D/2D gels
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    Centrifugal filter device/CHAPS
    Dialysis
    Hot SDS