Method optimisation for peptide profiling of microdissected breast carcinoma tissue by matrix-assisted laser desorption/ionisation-time of flight and matrix-assisted laser desorption/ionisation-time of flight/time of flight-mass spectrometry.
Umar A, Dalebout JC, Timmermans AM, Foekens JA, Luider TM
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to evaluate the utility of four different denaturing solutions in preparation of laser-microdissected cells for MADLI-TOF-MS assessment. Specimens were frozen and post-fixed with ethanol.
Summary of Findings
The authors report that few peptide peaks were detected when whole section or laser microdissected samples were prepared in urea or trifluoroethanol/NH4HCO3 buffers. Those prepared in RapiGest or SDS produced better results; and the ratio of signal to noise was best using SDS. Importantly, little overlap was observed among peaks when different denaturing buffers were used, suggesting buffer-specific results may be complimentary to one another. Prior preparation of whole-section samples on a monolithic HPLC column increased the number of peaks detected four-fold, while fractionation did not increase the number of peaks in microdissected samples.
Biospecimens
TissueBreastPreservation Types
FrozenEthanolDiagnoses
NeoplasticCarcinomaPlatforms
PeptideMALDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Laser microdissected cellsWhole sectionBiospecimen Acquisition Type of collection container/solution LoBind Eppendorf tubesMicrofuge tubeAnalyte Extraction and Purification Analyte isolation method Fractionation on monolithic HPLC columnNo fractionationMALDI-TOF MS Specific Reaction solution 0.1% RapiGest0.1% SDSTrifluoroethanol/NH4HCO3Urea