Urine profiling by SELDI-TOF/MS: monitoring of the critical steps in sample collection, handling and analysis.
Papale M, Pedicillo M C, Thatcher B J, Di Paolo S, Lo Muzio L, Bufo P, Rocchetti M T, Centra M, Ranieri E, Gesualdo L
Purpose
This paper conducted a comparative assessment of the effects of preanalytical (collection time of day, gender, storage at room temperature, freeze thaw cycling) and sample preparatory (centrifugation, denaturing solution) variables on the protein profiles of urine biospecimens.
Conclusion
Urine storage at room temperature resulted in a time-dependent reduction in peak number, which was only attenuated by the presence of protease inhibitors for up to 2 hours. While protein profile was unaffected by the time of day of collection, peak intensity varied. Inter-subject profile variability was gender-dependent, and greater in females. Urine centrifugation yielded a 23% increase in peak number. The authors recommend timed collection of urine, rapid analysis or freezing of urine specimens, and the use of several chip arrays for analysis of the urine proteome due to the small degree of spectral overlap among arrays.
Studies (2)
Purpose
The purpose of this study was to determine if patient (gender), specimen collection (time of day), and specimen handling (storage duration at room temperature, freeze thaw cycling) affect the protein profiles of urine biospecimens.
Summary of Findings
Protein profile was not significantly altered by the time of day of urine collection (morning, afternoon), although variations in peak intensity was observed, possibly indicative of the degree of urine dilution. Storage of urine samples at room temperature resulted in a time-dependent decrease, effects which could only be attenuated by protease inhibitors for the first 2 hours. Freeze thaw cycling (up to 5 times) of urine specimens yielded no effects on protein profile or peak intensity. Although a large degree of inter-subject variability was observed among protein profiles, the degree of variability was greatest among females.
Biospecimens
FluidUrinePreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinSELDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Patient gender FemaleMaleBiospecimen Aliquots and Components Aliquot sequential collection Collected in afternoonCollected in morningStorage Freeze/thaw cycling 1 freeze/thaw cycles2 freeze/thaw cycles3 freeze/thaw cycles4 freeze/thaw cycles5 freeze/thaw cyclesStorage Time at room temperature 0 h2 h4 h8 hAnalyte Extraction and Purification Protease inhibitor With protease inhibitorsWithout protease inhibitors
Purpose
The purpose of this study was to determine if variations in preanalytical biospecimen preparation (centrifugation, denaturing solution) or the type of chip used for analysis affects the protein profile of urine biospecimens.
Summary of Findings
Analysis of singular samples using different chips yielded little overlap among protein profiles, with as little as 1.3% of peaks shared across arrays. Centrifugation of a urine sample prior to analysis increased the number of peaks by 23%. Results of various denaturation solutions were chip-dependent.
Biospecimens
FluidUrinePreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinSELDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) SELDI-TOF MS Specific Reaction solution Chip-specific binding bufferDTTUrea + CHAPSUrea + CHAPS + DTTSELDI-TOF MS Specific Technology platform CM10 ProteinChipH50 ProteinChipIMAC-30 ProteinChipQ10 ProteinChip