Urine protein profiling with surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry.
Schaub S, Wilkins J, Weiler T, Sangster K, Rush D, Nickerson P
Purpose
The purpose of this paper was to determine if the urine protein profile, as determined by surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS), was influenced by patient (gender, blood in the urine, urine dilution), acquisition (sequential collection), storage (duration, freeze thaw cycling), or analytical factors (matrix composition, instrument settings).
Conclusion
The authors report that matrix composition and instrument settings affected peak detection and reproducibility. While 5 freeze-thaw cycles resulted in a loss of peaks, 4 cycles or less had minimal effects on urine protein profiles. Effects of storage duration were dependent upon gender and sequential collection: storage of mid-stream specimens for 3 days at 4 degrees C yielded little to no effect in terms of the number of peaks observed, while storage of first stream samples resulted in new low molecular weight peaks; and comparison among first and mid-stream specimens yielded differences in the spectral profile for females alone. The presence of blood in the urine specimen introduced new peaks corresponding to serum proteins. Fluid loading that exceeded 2L per day also impacted the spectral profile of urine specimens.
Studies (2)
Purpose
The purpose of this paper was to determine if the urine protein profile, as determined by surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS), was influenced by analytical factors (matrix composition, instrument settings).
Summary of Findings
Varying concentrations (20-100%) of matrix solutions resulted in a universal effect on observed peak number. Spot sampling protocol also influenced peak number in diluted and undiluted urine specimens.
Biospecimens
FluidUrinePreservation Types
FrozenDiagnoses
Not specifiedPlatforms
ProteinSELDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot size/volume Concentrated urineDiluted urine (1:16)Diluted urine (1:2)Diluted urine (1:4)Diluted urine (1:8)Undiluted urineSELDI-TOF MS Specific Reaction solution 20%, 35%, 50%, or 100% CHCA20%, 35%, 50%, or 100% SPA
Purpose
The purpose of this paper was to determine if the urine protein profile, as determined by surface-enhanced laser-desorption/ionization time-of-flight mass spectrometry (SELDI-TOF-MS), was influenced by patient (gender, blood in the urine, urine dilution), or acquisition related factors (sequential collection).
Summary of Findings
First stream urine specimens collected from females only differed from mid-stream specimens in the 3-3.5 kD range. Storage of mid-stream urine specimens for 3 days at room temperature or 4 degrees C yielded little to no effect in terms of the number of peaks observed, while storage of first stream specimens resulted in new low molecular weight peaks. Five freeze thaw cycles resulted in a loss of peaks while 4 or less freeze thaw cycles did not significantly alter spectral profiles. The presence of blood in urine specimens resulted in the appearance of peaks consistent with serum proteins. Fluid loading of 4L per day affected the spectral profile while 2L per day had little effect.
Biospecimens
FluidUrinePreservation Types
FrozenDiagnoses
NormalPlatforms
ProteinSELDI-TOF MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Patient gender FemaleMaleBiospecimen Aliquots and Components Aliquot sequential collection First-void urine (the first 10-20 ml excreted)Mid-stream urine (the next 50-80 ml excreted)Biospecimen Aliquots and Components Blood and blood products Presence of blood in urine specimenStorage Freeze/thaw cycling 1 freeze-thaw cycles2 freeze-thaw cycles3 freeze-thaw cycles4 freeze-thaw cycles5 freeze-thaw cyclesStorage Storage duration 3 daysProcessing within 2 h of collectionStorage Storage temperature -70 degrees C4 degrees CRoom temperature