Human postmortem brain tissue and 2-mm tissue microarrays.
Kauppinen T, Martikainen P, Alafuzoff I
Purpose
The purpose of this paper was to assess the influence of various pretreatment and staining techniques, slide type, and patient postmortem interval (PMI; 16-278 h) on the performance of different brain regions in tissue microarrays.
Conclusion
The authors report that the loss of core samples from the slide was most influenced by the type of slide. Superfrost slides, which employ electrostatic attraction to affix sections, suffered the least sample loss (approximately 5% of samples). Samples from deeper brain regions were more likely to be lost, perhaps due to insufficient fixation. Pretreatment and staining methods did not significantly influence sample loss from slides employing electrostatic attraction; significant sample loss was seen for slides employing mechanical attraction of samples when heat pretreatments were used. PMI influenced sample loss when an autoclave pretreatment was used. Staining quality and reproducibility were influenced by PMI, slide type, and sample position on the slide.
Studies (2)
Purpose
The purpose of this study was to evaluate sample loss from tissue microarray slides when employing different slide types, antigen retrieval approaches, brain regions, and PMIs.
Summary of Findings
PMI adversely influenced sample loss from microarray slides when pretreatment was not performed, although results were also dependent upon brain region and slide type (sample loss was more prevalent with ChemMate slides). Sample loss from slides was more frequent with longer PMI after autoclaving compared to microwave heating. Antigen retrieval solutions resulted in solution- and slide- dependent core sample loss: loss was more frequent with APES-coated slides) while treatment with 80% formic acid for up to 6 hours did not induce sample loss.
Biospecimens
TissueBrainPreservation Types
FormalinDiagnoses
Alzheimer's DiseaseCardiovascular DiseasePneumonia/Respiratory InfectionAutopsyPlatforms
ProteinImmunohistochemistryProteinTissue microarrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Postmortem interval 16 h278 h96 hBiospecimen Acquisition Biospecimen location Brain: gray matterBrain: nucleiBrain: white matterBiospecimen Aliquots and Components Type of slide ChemMate (DakoCytomation); electrostaticLocally made; mechanical attractionSuperFrost Plus (Menzel-Glaser); electrostaticAnalyte Extraction and Purification Temperature of heat-induced retrieval Autoclave methodMicrowave method
Purpose
The purpose of this study was to evaluate staining quality and reproducibility when employing different slide types, brain regions, and PMIs.
Summary of Findings
The majority of core samples displayed appropriate and reproducible staining, although sample location on the slide impacted staining quality. Samples located in the corners of slides stained poorly compared to those in the center. A longer PMI positively influenced staining quality when two cases were compared (16 versus 96 h), although slide-dependent variability was also observed.
Biospecimens
TissueBrainPreservation Types
FormalinDiagnoses
Alzheimer's DiseaseCardiovascular DiseasePneumonia/Respiratory InfectionAutopsyPlatforms
ProteinImmunohistochemistryProteinTissue microarrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Postmortem interval 16 h278 h96 hBiospecimen Acquisition Biospecimen location Brain: gray matterBrain: nucleiBrain: white matterBiospecimen Aliquots and Components Type of slide ChemMate (DakoCytomation); electrostaticLocally made; mechanical attractionSuperFrost Plus (Menzel-Glaser); electrostaticTissue microarray Specific Specimen position Center of block/slidePeriphery of block/slide